Question No. 1

Which statement about the configuration of a VXLAN is true?

Answer: A

Question No. 2

A Cisco Nexus 2000 Series Fabric Extender is connected to two Cisco Nexus 5000 Series switches via a vPC link. After both Cisco Nexus 5000 Series switches lose power, only one switch is able to power back up. At this time, the Cisco Nexus 2000 Series Fabric Extender is not active and the vPC ports are unavailable to the network.

Which action will get the Cisco Nexus 2000 Series Fabric Extender active when only one Cisco Nexus 5000 Series switch is up and active?

Answer: C

The vPC consistency check message is sent by the vPC peer link. The vPC consistency check cannot be performed when the peer link is lost. When the vPC peer link is lost, the operational secondary switch suspends all of its vPC member ports while the vPC member ports remain on the operational primary switch. If the vPC member ports on the primary switch flaps afterwards (for example, when the switch or server that connects to the vPC primary switch is reloaded), the ports remain down due to the vPC consistency check and you cannot add or bring up more vPCs.

Beginning with Cisco NX-OS Release 5.0(2)N2(1), the auto-recovery feature brings up the vPC links when one peer is down. This feature performs two operations:

* If both switches reload, and only one switch boots up, auto-recovery allows that switch to assume the role of the primary switch. The vPC links come up after a configurable period of time if the vPC peer-link and the peer-keepalive fail to become operational within that time. If the peer-link comes up but the peer-keepalive does not come up, both peer switches keep the vPC links down. This feature is similar to the reload restore feature in Cisco NX-OS Release 5.0(2)N1(1) and earlier releases. The reload delay period can range from 240 to 3600 seconds.

* When you disable vPCs on a secondary vPC switch because of a peer-link failure and then the primary vPC switch fails, the secondary switch reenables the vPCs. In this scenario, the vPC waits for three consecutive keepalive failures before recovering the vPC links.

http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/operations/n5k_vpc_ops.html

Question No. 3

Without having access to Fabric Path show commands, how can you confirm whether Fabric Path is configured on the two vPC peer 7K-3 and 7K-4?

Answer: A

Question No. 4

You plan to configure a SAN zone set, which two facts should you consider

Answer: C, D

Question No. 5

Refer to the exhibit.

Which result occurs if N7K-2 fails and then recovers?

Answer: D

Question No. 6

If vPC peer keepalives are used between vPC peers, which VRF is used by default?

Answer: A

Question No. 7

Assuming hello PDU authentication has been disabled, which command re-enables the feature on a FabricPath interface?

Answer: C

Question No. 8

When implementing Cisco Adapter FEX, which setting on the virtual interface card on the Cisco UCS C-Series Server must be configured?

Answer: C

Question No. 9

What is the Overlay Transport Virtualization site VLAN used for?

Answer: A

Question No. 10

Refer to the exhibit.

You have a suboptimal outbound routing issue in the datacenter. Which two options you can use to resolve the issue? (Choose two)

Answer: A, B